Schneider Micrologic 6.0 H 47062 Masterpact LSIG Circuit Barker Trip Unit

$499.99

Product Conditioned

NEW

Free Shipping apply to all orders over $199

Guaranteed Money Back in 30 days return.

24/7 Customer Support

Share:

Schneider Micrologic 6.0 H 470...

$499.99

Out of stock

Hotline Order:

(+101) 5620 - 8155

Email ID:

xstore@support.com

 

Main
Range MasterPact
Range of produc MasterPact NW
Product or component type Control unit
Trip unit name MicroLogic 6.0 H
Trip unit technology Electronic
Range compatibility Masterpact NW08…40
Masterpact NW40b…63
Masterpact NW H10
Masterpact NW H2 corrosion protection
Device application Distribution
Number of poles 3P
4P
Protected poles description 4t
3t
3t + N/2
Trip unit protection functions Selective + earth-fault protection
Protection type for overload protection (long time)
for short time short-circuit protection
for instantaneous short-circuit protection
for earth fault
Trip unit rating 800 A at 50 °C
1000 A at 50 °C
1250 A at 50 °C
1600 A at 50 °C
2000 A at 50 °C
2500 A at 50 °C
3200 A at 50 °C
4000 A at 50 °C
5000 A at 50 °C
6300 A at 50 °C
Network type AC
Network frequency 50/60 Hz
Circuit breaker mounting mode Drawout

 

Complementary
Long-time pick-up adjustment type Ir (thermal protection) Adjustable 9 settings
[Ir] long-time protection pick-up adjustment range 0.4…1 x In
Long-time protection delay adjustment type tr Adjustable 9 settings
[tr] long-time protection delay adjustment range 0.7…16.6 s at 7.2 x Ir
0.7…24 s at 6 x Ir
12.5…600 s at 1.5 x Ir
thermal memory 20 mn
Short-time protection pick-up adjustment type Isd Adjustable 9 settings
[Isd] Short-time protection pick-up adjustment range 1.5…10 x Ir
Short-time protection delay adjustment type tsd Adjustable
[tsd] Short-time protection delay adjustment range 0…0.4 s I²t=off
0.1…0.4 s I²t=on
Instantaneous protection pick-up adjustment type Ii Adjustable 9 settings
[Ii] instantaneous protection pick-up adjustment range Off
2…15 x In
Ground-fault protection pick-up adjustment type Ig Adjustable 9 settings
[Ig] ground-fault protection pick-up adjustment range 0.2…1 x In for 400 A < In < 1250 A
0.3…1 x In for In <= 400 A
500…1200 A for In >= 1250 A
Ground-fault protection time delay adjustment type tg Adjustable
[tg] ground-fault protection time delay adjustment range 0…0.4 s I²t=off
0.1…0.4 s I²t=on
earth-leakage protection Without
Zone selective interlocking ZSI With
Local signalling 3 LEDs (red) for electrical fault
1 LED (red) for internal error
Display type Digital display
Type of measurement Harmonics meter
Power meter
communication of data Measurement readout
Protection and alarm settings
Maintenance indicators

 