• RACAL ALARM REPEATER UNIT MARINE 77251 GROUP CONTROL UNIT 1 TSE 5 AND 1 TSF 8 1
  • RACAL ALARM REPEATER UNIT MARINE 77251 GROUP CONTROL UNIT 1 TSE 5 AND 1 TSF 8 1
  • RACAL ALARM REPEATER UNIT MARINE 77251 GROUP CONTROL UNIT 1 TSE 5 AND 1 TSF 8 2
  • RACAL ALARM REPEATER UNIT MARINE 77251 GROUP CONTROL UNIT 1 TSE 5 AND 1 TSF 8 3
  • RACAL ALARM REPEATER UNIT MARINE 77251 GROUP CONTROL UNIT 1 TSE 5 AND 1 TSF 8 4
  • RACAL ALARM REPEATER UNIT MARINE 77251 GROUP CONTROL UNIT 1 TSE 5 AND 1 TSF 8 5
  • RACAL ALARM REPEATER UNIT MARINE 77251 GROUP CONTROL UNIT 1 TSE 5 AND 1 TSF 8 6
  • RACAL ALARM REPEATER UNIT MARINE 77251 GROUP CONTROL UNIT 1 TSE 5 AND 1 TSF 8 7
  • RACAL ALARM REPEATER UNIT MARINE 77251 GROUP CONTROL UNIT 1 TSE 5 AND 1 TSF 8 8
  • RACAL ALARM REPEATER UNIT MARINE 77251 GROUP CONTROL UNIT 1 TSE 5 AND 1 TSF 8 9
  • RACAL ALARM REPEATER UNIT MARINE 77251 GROUP CONTROL UNIT 1 TSE 5 AND 1 TSF 8 10

Hotline Order:

(+91) 97257 54777

Email ID:

shipnavstore@gmail.com

RACAL ALARM REPEATER UNIT MARINE 77251 GROUP CONTROL UNIT-1 TSE 5 AND 1 TSF 8 15:49

34,454.00

SKU: 1307 Brand:
Product Conditioned

USED

or

Free Shipping apply to all orders over $199

Guaranteed Money Back in 30 days return.

24/7 Customer Support

Share:

RACAL ALARM REPEATER UNIT MARINE 77251 GROUP CONTROL UNIT 1 TSE 5 AND 1 TSF 8 1 RACAL ALARM REPEATER UNIT MARI...

34,454.00

2 in stock

Hotline Order:

(+101) 5620 - 8155

Email ID:

xstore@support.com

The Racal Alarm Repeater Unit, Marine 77251 is a central control and display panel for a ship’s machinery monitoring and alarm system. Its primary function is to provide engineers on the bridge and in control rooms with a clear, centralized status of all critical vessel parameters (like engine temperature, pressure, fluid levels, etc.).

When a sensor on the engine or other systems detects a fault or a value moving outside its normal range, it sends a signal to this unit. The 77251 then provides both a visual and audible alarm to alert the crew, allowing for quick response to potential problems.


Component Breakdown

Your specific designation, “GROUP CONTROL UNIT-1 TSE 5 AND 1 TSF 8 SEO,” describes the exact configuration of the unit. Here’s what each part means:

1. RACAL ALARM REPEATER UNIT MARINE 77251

  • Racal: The manufacturer, a highly respected British electronics company, particularly in marine and defense navigation/communication systems.

  • Alarm Repeater Unit: This is the core function. It “repeats” or displays the status of alarms that are first detected by remote sensors and primary monitoring units in the engine control room. It’s often installed in secondary locations like the bridge, the chief engineer’s cabin, or the mess room to extend the alarm coverage.

  • 77251: This is the specific model number for this group control unit chassis or main assembly.

2. GROUP CONTROL UNIT

This is the main housing or chassis that contains the individual alarm modules. It provides the common power, audible alarm, and logic for all the modules plugged into it.

3. Module Configuration: “1 TSE 5 AND 1 TSF 8”

This is the most important part, detailing what is actually installed in the unit. Racal used a modular system where different cards (modules) could be plugged in to monitor different types of signals.

  • TSE 5: This is a monitoring module.

    • TSE: Likely stands for a specific type of input channel, probably for monitoring temperature or a similar analog value from a single sensor.

    • 5: Indicates this single TSE module is configured to monitor 5 separate alarm points or channels. It would have 5 corresponding lamps on the front display.

  • TSF 8: This is another monitoring module.

    • TSF: Likely stands for a different type of input, possibly for status or on/off (binary) signals, like a pump running/stopped or a tank level high/low switch.

    • 8: Indicates this single TSF module is configured to monitor 8 separate alarm points or channels.

Summary of this configuration: This specific unit is equipped to monitor a total of 13 alarm points (5 from the TSE module + 8 from the TSF module).

4. SEO

This is an internal code that could stand for several things, most likely:

  • A specific factory configuration or build option.

  • hardware revision or production batch code.

  • An acronym for a standard feature set (e.g., Standard Equipment Option).


Key Features and Typical Operation

  • Visual Indication: Each alarm point (for a total of 13 in your unit) would have its own dedicated red LED or lamp on the front panel. The panel would also have a common “General Alarm” flashing light.

  • Audible Alarm: A built-in buzzer or sounder would activate when any alarm triggered.

  • Acknowledge Button: Pressing an “Accept” or “Acknowledge” button would silence the audible alarm, but the visual light for the specific fault would remain lit (often changing from flashing to steady) until the underlying problem was resolved and the sensor returned to normal.

  • Test Button: A button to test all the indicator lamps and the sounder to ensure the system is functional.

  • Modular Design: The system’s great advantage was its flexibility. Ships could order exactly the number and type of monitoring points they needed.

We're here when you need us

Get a Quick Quote

Complete our online form.

Call US

Speak to one of our team.

Live Chat

Send us a message