• Omron E5EN HAA2HH03B – FLK DIGITAL CONTROLLER N1875 L NO 2184MR 2
  • Omron E5EN HAA2HH03B – FLK DIGITAL CONTROLLER N1875 L NO 2184MR 1
  • Omron E5EN HAA2HH03B – FLK DIGITAL CONTROLLER N1875 L NO 2184MR 2
  • Omron E5EN HAA2HH03B – FLK DIGITAL CONTROLLER N1875 L NO 2184MR 3
  • Omron E5EN HAA2HH03B – FLK DIGITAL CONTROLLER N1875 L NO 2184MR 4
  • Omron E5EN HAA2HH03B – FLK DIGITAL CONTROLLER N1875 L NO 2184MR 5
  • Omron E5EN HAA2HH03B – FLK DIGITAL CONTROLLER N1875 L NO 2184MR 6
  • Omron E5EN HAA2HH03B – FLK DIGITAL CONTROLLER N1875 L NO 2184MR 7
  • Omron E5EN HAA2HH03B – FLK DIGITAL CONTROLLER N1875 L NO 2184MR 8
  • Omron E5EN HAA2HH03B – FLK DIGITAL CONTROLLER N1875 L NO 2184MR 9

Hotline Order:

(+91) 97257 54777

Email ID:

shipnavstore@gmail.com

Omron E5EN-HAA2HH03B – FLK DIGITAL CONTROLLER N1875 L NO 2184MR 12:29

$179.99

SKU: 829 Brand:
Product Conditioned

USED

or

Free Shipping apply to all orders over $199

Guaranteed Money Back in 30 days return.

24/7 Customer Support

Share:

Omron E5EN HAA2HH03B – FLK DIGITAL CONTROLLER N1875 L NO 2184MR 2 Omron E5EN-HAA2HH03B – FLK DIG...

$179.99

4 in stock

Hotline Order:

(+101) 5620 - 8155

Email ID:

xstore@support.com

Omron E5EN-HAA2HH03B – FLK DIGITAL CONTROLLER N1875 L NO 2184MR

Power supply voltage No D in model number: 100 to 240 VAC, 50/60 Hz
D in model number: 24 VAC, 50/60 Hz; 24 VDC
Operating voltage range 85% to 110% of rated supply voltage
Power consumption 100 to 240 VAC: 12 VA
24 VAC/VDC: 8.5 VA (24 VAC)/5.5 W (24 VDC)
Sensor input Any of the following can be selected.
Thermocouple: K, J, T, E, L, U, N, R, S, B, W, or PL II
Platinum resistance thermometer: Pt100 or JPt100
Current input: 4 to 20 mA or 0 to 20 mA
Voltage input: 1 to 5 V, 0 to 5 V, or 0 to 10 V
Input impedance Current input: 150 Ω max., Voltage input: 1 MΩ min. (Use a 1:1 connection when connecting the ES2-HB-N.)
Control method ON/OFF control or 2-PID control (with auto-tuning)
Control
output
Relay output Output Unit (Install the Output Unit (sold separately).)
Voltage output
(for driving SSR)
Current output
Linear voltage
output
Relay output for
position-
proportional control
Relay output: Open and close: SPST-NO, 250 VAC, 1 A (including in-rush current), electrical life: 100,000 operations min.
Potentiometer input: Must be between 100 Ω and 2.5 kΩ for maximum open position.
Auxiliary
output
Number of outputs 2 or 3 max.
Output
specifications
Relay output: SPST-NO, 250 VAC, 3 A (resistive load), electrical life: 100,000 operations, minimum applicable load: 5 V, 10 mA
Event
input
Number of outputs 2 or 4 (with an E53-AKB)
External contact
input specifications
Contact input: ON: 1 kΩ max., OFF: 100 kΩ min.
Non-contact input: ON: Residual voltage: 1.5 V max., OFF: Leakage current: 0.1 mA max.
Current flow: Approx. 7 mA per contact
Logic
operations
Number of
operations
8 max.
Operations • Logic operation:
Any of the following four patterns can be selected. The input status may be inverted.
(A and B) or (C and D), (A or C) and (B or D), A or B or C or D, A and B and C and D (A, B, C, and D are four inputs.)
• Delay:
ON delay or OFF delay for the results of the logic operation given above.
Setting time: 0 to 9999 s or 0 to 9999 min
• Output inversion: Possible
Output One work bit per operation
Work bit
assignment
Any of The following can be assigned to up to eight work bits (logic operation results): Event input operations, auxiliary outputs, or control outputs.
Transfer
outputs
Number of outputs 1 max. (Depends on model. Models with transfer output (F in model number)
Output
specifications
Current output: 4 to 20 mA DC, Load: 600 Ω max., Resolution at 4 to 20 mA: Approx. 10,000
RSP
input
Number of inputs 1
Signal type Current input: 4 to 20 mA (input impedance: 150 Ω ±10%)
Analog input scaling Scaling of signal to engineering units (EU)
-19,999 to 30,000 (display: 30,000 max.)
Accuracy (±0.2% of FS) ±1 digit max.
Input sampling
period
60 ms
Setting method Set digitally using keys on the front panel or by using the RSP input.
Indication method 11-segment digital display and individual indicators (7-segments displays also possible)
Character height: E5AN-H: PV: 15.8 mm, SV: 9.5 mm, MV: 6.8 mm; E5EN-H: PV: 11.8 mm, SV: 8.1 mm, MV: 5.8 mm
Content of 3-level display: PV/SV/MV, PV/SV/Bank No., or soak time remain
Number of digits: 5 for PV and SV, 4 for MV
Bank switching Supported (number of banks: 8)
Local SP, alarm settings, PID sets (PID constants, MV upper limit, MV lower limit, etc.)
Other functions Manual output, heating/cooling control, loop burnout alarm, SP ramp, other alarm functions, heater burnout detection, 40% AT, 100% AT, MV limiter, input digital filter, self-tuning, temperature input shift, run/stop, protection functions, control output ON/OFF counter, extraction of square root, MV change rate limit, PV/SV status display, logic operations, automatic cooling coefficient adjustment
Ambient operating temperature -10 to 55°C (with no condensation or icing), for 3-year warranty: -10 to 50°C
Ambient operating humidity 25% to 85%
Storage temperature -25 to 65°C (with no condensation or icing)
PROCESS CONTROL EQUIPMENT 3NRS
LOT NO – 2184MR
MANUFACTURER – OMRON CORPORATION
MADE IN CHINA