Hotline Order:

(+91) 97257 54777

Email ID:

shipnavstore@gmail.com

MOXA IOLOGIK R1212-T IOLOGIK R1200 SERIES UNIVERSAL I/O, 8 DLS, 8 DIOS P/N 0094 17:37

17,707.00

SKU: 1172 Brand:
Product Conditioned

USED

or

Free Shipping apply to all orders over $199

Guaranteed Money Back in 30 days return.

24/7 Customer Support

Share:

MOXA IOLOGIK R1212 T IOLOGIK R1200 SERIES UNIVERSAL IO 8 DLS 8 DIOS PN 0094 3 MOXA IOLOGIK R1212-T IOLOGIK R...

17,707.00

1 in stock

Hotline Order:

(+101) 5620 - 8155

Email ID:

xstore@support.com

BRAND: MOXA
MODEL: IOLOGIK R1212-T
IOLOGIK R1200
SERIES UNIVERSAL
8 DLS, 8 DIOS
PRODUCTION S/N: TBZJB1093045
INPUT: 12-48 VDC, 0.75A(MAX), CLASS2
REV: 1.1.2
MSIP-REM-MXA-IOLOGIKR1212
AIR TEMPERATURE: 75 C
P/N: 3093004000094
MADE IN TAIWAN

The IOLOGIK R1212-T is a “Universal I/O” device because its 8 DIO (Digital Input/Output) channels are individually software-configurable. This means you can tailor each channel to your specific needs, providing exceptional flexibility.

1. Channel Breakdown:

  • 8 Digital Input (DI) Channels: These are dedicated inputs for reading the state (ON/OFF) from devices like push buttons, switches, proximity sensors, or relay contacts.

  • 8 Digital Input/Output (DIO) Channels: Each of these 8 channels can be individually configured to act as either:

    • A Digital Input (DI), or

    • A Digital Output (DO) for controlling devices like indicators, alarms, solenoid valves, or small relays.

This gives you a maximum flexible configuration of 16 Digital Inputs and 8 Digital Outputs, or any combination in between.

2. Key Features and Capabilities:

  • Flexible I/O Configuration: The standout feature is the software-configurable DIOs, allowing for easy setup changes without rewiring.

  • Built-in “T” Feature (Turbo Ring): The “-T” in the model name indicates it includes Moxa’s proprietary Turbo Ring technology. This provides fast network redundancy (recovery time < 20 ms) for highly reliable networks that must withstand a single cable break.

  • Easy Integration:

    • MQTT Protocol: Native support for the lightweight MQTT protocol, ideal for IoT and SCADA systems for pushing data to brokers like AWS IoT or Azure IoT Hub.

    • Modbus TCP Support: Acts as a Modbus TCP slave, making it compatible with most SCADA, HMI, and PLC systems.

  • Rich Monitoring & Control Functions:

    • I/O On Demand: The module only sends data when the state changes or when polled, reducing network traffic.

    • Report by Exception: Sends data immediately when a pre-defined event (like a DI state change) occurs.

    • Counter & Frequency Measurement: The DI channels can be used to count pulses or measure the frequency of incoming signals.

  • Rugged Design:

    • Operating temperature range suitable for industrial environments (-40 to 75°C).

    • Dual 12 to 48 VDC power inputs for redundancy.

    • DIN-rail mounting for easy installation in control panels.


Typical Applications

The R1212-T is used for monitoring and controlling digital signals remotely over an Ethernet network. Common applications include:

  • Factory Automation: Monitoring machine status (sensors, interlocks) and controlling actuators.

  • Building Management Systems (BMS): Monitoring door/window contacts, smoke detectors, and controlling lighting or HVAC systems.

  • Environmental Monitoring: Monitoring alarm outputs from other equipment.

  • Remote Site Management: Monitoring security fences, gate status, and power failures at unmanned sites.

  • Transportation Systems: Monitoring signals and controlling indicators in tunnels or along railways.

Summary Table

Feature Specification
Model IOLOGIK R1212-T
Series IOLOGIK R1200
Part Number (P/N) 0094
I/O Type Universal Digital I/O
Digital Inputs (DI) 8 dedicated channels
Digital I/O (DIO) 8 software-configurable channels (can be set as DI or DO)
Max. Configurable DI 16
Max. Configurable DO 8
Network Redundancy Turbo Ring (recovery < 20 ms)
Communication Protocols Modbus TCP, MQTT
Power Supply Dual 12 to 48 VDC
Mounting DIN-rail

In essence, the Moxa IOLOGIK R1212-T (P/N 0094) is a flexible, resilient, and powerful remote I/O solution that simplifies the process of connecting a large number of digital sensors and actuators to an industrial Ethernet network.