CAREL PC0E004850 EXPANSION MODULE RS485 PCO REV. 2.060
- BRAND: CAREL
- PCO CAREL
- RS485 EXPANSION BOARD
- MFG DATE: 31-MAY-2018
- SN: C00052987
- REV: 2.060
- CODE:PC0E004850
- MADE IN USA
CAREL PC0E004850 Expansion Module – Product Description
The CAREL PC0E004850 is an RS485 Expansion Module designed for the pCO series of programmable HVAC/R controllers. Its primary function is to expand the I/O (Input/Output) capacity of a master pCO controller, allowing it to interface with more sensors, actuators, and devices than its built-in terminals allow.
The “REV. 2.060” indicates the hardware revision of the module, and “SEO” is likely an internal manufacturing or product code.
Key Features
- 
Communication Interface: Equipped with an RS485 serial bus. This is a robust, industry-standard communication protocol ideal for building automation systems, allowing for long-distance communication (up to 1200 meters) and connectivity of multiple devices on a single bus. 
- 
Plug-and-Play Expansion:Â Connects directly to the pCO system’s expansion bus. It is automatically recognized by the master pCO controller (once configured in the software), simplifying system integration. 
- 
Additional I/O Capacity:Â The module provides a set of configurable digital and analog inputs and outputs. The exact number and type can vary, but a typical configuration for such a module is: - 
Analog Inputs (AI):Â For reading signals from sensors (e.g., temperature, pressure, humidity sensors using 0-10V, 4-20mA, or NTC/PTC thermistors). 
- 
Digital Inputs (DI):Â For reading on/off statuses (e.g., pressure switches, alarm contacts, flow switches). 
- 
Digital Outputs (DO) or Relays:Â For controlling devices (e.g., contactors, solenoid valves, alarm indicators). These are often configurable as PWM (Pulse Width Modulation) outputs. 
 
- 
- 
pCO Ecosystem Integration: Fully integrated with the CAREL pCO environment. All I/O points on this expansion module are treated as native points of the master controller within the pCO+` design and configuration software.
- 
Compact Design:Â Designed to fit seamlessly with other pCO modules in a DIN rail enclosure, saving panel space. 
Primary Function and Application
The PC0E004850 is used when the I/O capabilities of a central pCO controller (e.g., a pCO5 or pCO3) are insufficient for a given application.
Typical Use Cases:
- 
HVAC Systems:Â Adding extra temperature sensors for zoning, pressure sensors for VAV systems, or control outputs for additional valves and dampers. 
- 
Refrigeration Systems:Â Expanding a controller for a multi-compressor rack to include more pressure transducers, case temperature sensors, or alarm contacts for individual cases. 
- 
Energy Management:Â Integrating additional power meters or sub-meters into a building management system run by a pCO controller. 
Technical Specifications (Generic)
- 
Power Supply:Â Typically powered from the pCO system’s main power supply or via the expansion bus. 
- 
Communication Protocol: RS485, following CAREL’s proprietary pCO network protocol or sometimes standard Modbus RTU.
- 
Isolation:Â Galvanic isolation between the communication bus and the I/O circuits is common to protect against electrical noise and surges. 
- 
Operating Environment:Â Standard industrial ratings for temperature and humidity. 
Configuration and Programming
- 
The module itself is not programmed independently. 
- 
It is configured entirely within the pCO+` software suite.
- 
The system programmer defines the master controller, adds the expansion module to the system layout, and then assigns each physical I/O point on the module a logical function within the application program (e.g., “Condenser Pressure Input,” “Alarm Horn Output”). 
 
				 
								













 
															 
                            
                         
                            
                         
                            
                         
                            
                        